LPCB Addressable Fire Alarm Heat Detector AW-D302 AW-D302 Addressable Heat Detector (Detector hereunder) is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic...
Product overview: AW-D302 Addressable Heat Detector (Detector hereunder) is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic coding. The detector realizes real-time acquisition of the in situ temperature data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel. When in a routing inspection, the detector indicator will blink. When there is a fire in the monitored area and the temperature has reached the alarm threshold, the fire alarm control panel will confirm a fire alarm according to the received message sent from the detector, and the detector indicator will light at the same time to indicate a fire alarm. The detector is suitable for such industrial and civil buildings that have a great deal of heat when fire takes place, such as kitchens, boiler rooms, generator rooms, drying workshops and smoking rooms and is not suitable for places with a great deal of smoke but little heat.
Product Features: Addressable Fire Alarm Heat Detector Features: 1) It can realize electronic coding and rewrite the address via coder in situ. 2) Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation. 3) It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel). 4) Non-polarity, two-bus connection that ensures convenient installation and maintenance. 5)Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently. 6)Built-in remote indicator output terminal, drive remote indicator lit when fire alarm
Technical parameters: Addressable Fire Alarm Heat Detector Technical parameters : Operating Voltage | Loop 24V(18V~28V) | Standby Current | <0.3mA | Alarm Current | <1.5mA (without remote indicator) <3.5mA (with remote indicator) | Class | A2 | Fire LED | Red, Flash in polling, and illuminate in alarming. | Remote indicator output | Polarity-sensitive output, directly connect to remote indicator (built in 10k resistor in series, max. output current is 2mA); The red indicator will blink in the monitoring status or remain lit in the alarm status. | Programming | Electronically addressed. | Programming Range | Occupying one address within 1~324. | Wiring | Loop: two wire, polarity-insensitive | Environmental Temperature | -10℃~+50℃ | Relative Humidity | ≤95%, non-condensing | Material of Enclosure | ABS | Dimension | Diameter: 100mm Height: 60mm(with the base) | Mounting Hole Distance | 44.5mm~64.3mm | Weight | About 115g(with the base) |
|