The name for quality electrical and AI products 
E-mail:Elroielectechventures@gmail.com  
Categories
   Dealers in artificial intelligent systems
   Intelligent solar powered cctv cameras and cctv regular cameras
   Fire alarm systems
     Fire alarm systems conventional types
     firealarm
     Fire panels
     Lpg gas detector:fire alarm
     Conventional Fire Alarm Control System LPCB
     Call Point & Electronic Sounders-FireAlarm
   Intelligent fire products
   Smart electrical and lighting products
   Intelligent healthcare products for patients and health personnel
   Intelligent aged care solutions
   Intruder alarms
   Access control
Contact us
ELROI ELECTRICAL
P.O.Box CT 7494
Cantonments - Accra
GHANA-WEST AFRICA

Osu Head Office
28th February Road,
Near Osu Police Post
Tel:+233 302 324 780

Dansoman Branch
off the Russia Road,
Opposite Modex Filling Station
Cell:+233 277 551 107 
Elroielectechventures@gmail.com
 
- Fire alarm systems - Fire alarm systems conventional types - Standalone Wifi Smoke Detector AW-D611W

Product details:

Standalone Wifi Smoke Detector AW-D611W
The Standalone Wifi Smoke Detector detector is a photo-detector that uses the most advanced optical sensing chamber.It is designed to provide open area protection without wiring, and it is easy to ins...

Product overview:
The Standalone Wifi Smoke Detector detector is a photo-detector that uses the most advanced optical sensing chamber.It is designed to provide open area protection without wiring, and it is easy to install and construct. 
When a fire alarm occurs, the indicator light will continue to light up, the buzzer will sound for a long time and the alarm data will continue to be sent to the cloud via Wifi, and the cloud will issue an APP alarm until the APP terminal is reset. When the battery is at a low voltage, the indicator light will flash, the buzzer will beep, and the data will be sent to the cloud via Wifi once and will be sent to the APP.The test button, indicator light, and buzzer can be used together for different tests and settings
 
How To Connect The WIFI Smoke Detector To Tuya App
The red indicator light on the detector can provide a full range of visibility alarm. Flashes once every minute, indicating that the detector is working.
 
Standalone Wifi Smoke Detector detector characteristics
Surface mounting
Loud sound warning
LED indicator
No wire connection(easy to install)
Automatic alarm for low battery voltage
Compatible with the latest EN-14604 standards
 
Standalone Wifi Smoke Detector detector Routine operation:
1) Button test: Under normal circumstances, click the button, the buzzer will beep once, and the LED will flash 2 times, indicating that the device is operating normally. 
 
2) Silence: Click the button under the fire alarm to silence the sound for 5 minutes, counting from the first silence, and it is not allowed to continue silence after 15 minutes. 
 
3) Fire alarm reset: press and hold the button for 3 seconds under fire alarm to reset
 
Wifi operation instructions:
1) Wi-Fi is powered on for the first time, initialized, wait for 3-5 seconds, wait for the module to return to Wi-Fi status, and perform related operations according to Wi-Fi status:
 
A. Intelligent distribution network, AP distribution network mode: it means that the module has not been equipped
with a network after the previous reset, and a new network is needed. Keep the network status, and the indicator light keeps flashing fast or slowly. 
 
B. The network is configured, but not connected to wifi or connected to wifi, but not connected to the cloud: Wait for wifi to connect to the cloud, if it is still not connected after 20s, Dididi will report a fault for 1 minute and then enter sleep, at least keep it on Electricity can be connected to the router for the first time
 
C. connected to the cloud: report the status once, then turn off the wifi and enter sleep.
Wireless test: Under normal circumstances, long press the button for 3 seconds to activate wireless and report dataonce. 
Wireless network configuration (or reset to re-configure network, or switch network configuration mode): When the network is not configured, long press for 3 seconds to enter the network configuration mode, and long press again for 3 seconds to switch to the network configuration mode; if the network is configured, long press 10 Seconds reset.



Related Products
Conventional heat detector with LPCB EN54 certification AW-CTD382
Conventional heat detector with LPCB EN54 certification AW-CTD382
Battery Standalone Smoke Detector GT-D611
Battery Standalone Smoke Detector GT-D611
Quick response Conventional Smoke Detector AW-CSD311
Quick response Conventional Smoke Detector AW-CSD311
LPCB EN54 approve conventional smoke detector AW-CSD381
LPCB EN54 approve conventional smoke detector AW-CSD381
711PH, Conventional photo optical smoke & heat detector
711PH, Conventional photo optical smoke & heat detector
711P, Conventional photo optical smoke detector
711P, Conventional photo optical smoke detector
711H, Conventional heat (rate of rise) detector
711H, Conventional heat (rate of rise) detector
611H-F,Conventional 90ºC fixed temperature detector
611H-F,Conventional 90ºC fixed temperature detector